Chapter 6 System Testing Gen 3 Site Controller System Manual
Site Controller Verication
6-8 68P80801E30-A 5/1/2002
The default line build out setting for each port is 0.
Example: Change line build out to -7.5dB
net b Setting LBO
0 0dB
1 -7.5dB
2 -15dB
ACG# net b
Line build out for port 0 [0]: 1
Line build out for port 1 [0]: 1
Line build out for port 2 [0]: 1
Line build out for port 3 [0]: 1
Current NIC configuration is:
Signaling: T1
T1 line build out:
on port 0: 1
on port 1: 1
on port 2: 1
on port 3: 1