68P80801E30-A 5/1/2002 6-7
Gen 3 Site Controller System Manual Chapter 6 System Testing
Site Controller Verication
5. At the ACG# prompt, type: status
This command checks the current status of Controller A.
E1/T1 Conguration
To configure the site controller for E1, enter “net e” at the ACG# prompt.
To configure the site controller for T1, enter “net t” at the ACG# prompt.
To configure the T1 Line Build Out settings, enter “net b” at the ACG#
prompt. For each port, enter:
ACG# status
Active/Standby Status: ACTIVE
MAC Address: XX:XX:XX:XX:XX:XX
Standby ACG MAC Address (No Standby ACG)
ACG# net e
Current NIC configuration is:
Signalling: E1
ACG# net t
Current NIC configuration is:
Signaling: T1
T1 line build out:
on port 0: 0
on port 1: 0
on port 2: 0
on port 3: 0