Chapter 6   System Testing Gen 3 Site Controller System Manual
Base Radio Registration
6-16 68P80801E30-A   5/1/2002
 
Cab/Pos number will not be displayed for Quad BRs with invalid cabinet/
position number and BRs that don’t respond successfully.
No information will be displayed for BRs that fail to respond at all. 
The service computer displays the following messages if the site controller 
cannot communicate with any BR.
Perform the following steps in case of unsuccessful response from one or 
more BRs:
1. Check the ethernet connection.
2. Check BR cabinet/position number.
3. Reset the BR.
iSC> ping br 
Cab/Pos Ethernet Address Platform
--------- --------------------- -------------
08:00:3e:c0:1c:18 Legacy BR
08:00:3e:c0:1c:19 Quad BR
iSC> ping br 
No BR responses received for ‘ping br’
Ping br is not successful