TN-5516/5518 User’s Manual Featured Functions
3-91
Using Syslog
This function provides the event logs for the syslog server. The function supports 3 configurable
syslog servers and syslog server UDP port numbers. When an event occurs, the event will be sent
as a syslog UDP packet to the specified syslog servers.
Syslog Server 1
Setting Description Factory Default
IP Address Enter the IP address of 1st Syslog server used by your
network.
None
Port Destination
(1 to 65535)
Enter the UDP port of 1st Syslog server. 514
Syslog Server 2
Setting Description Factory Default
IP Address Enter the IP address of 2nd Syslog server used by your
network.
None
Port Destination
(1 to 65535)
Enter the UDP port of 2nd Syslog server. 514
Syslog Server 3
Setting Description Factory Default
IP Address Enter the IP address of 3rd Syslog server used by your
network.
None
Port Destination
(1 to 65535)
Enter the UDP port of 3rd Syslog server. 514

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies ToughNet Switch TN-5500 series and is the answer not in the manual?

Moxa Technologies ToughNet Switch TN-5500 series Specifications

General IconGeneral
BrandMoxa Technologies
ModelToughNet Switch TN-5500 series
CategorySwitch
LanguageEnglish

Related product manuals