TN-5516/5518 User’s Manual Featured Functions
3-77
Port Events Warning e-mail is sent when…
Link-ON The port is connected to another device.
Link-OFF
The port is disconnected (e.g., the cable is pulled out,
or the opposing device shuts down).
Traffic-Overload
The port’s traffic surpasses the Traffic-Threshold for
that port (provided this item is Enabled).
Traffic-Threshold (%)
Enter a nonzero number if the port’s Traffic-Overload
item is Enabled.
Traffic-Duration (sec.)
A Traffic-Overload warning is sent every
Traffic-Duration seconds if the average
Traffic-Threshold is surpassed during that time
period.
NOTE
The Traffic-Overload, Traffic-Threshold (%), and Traffic-Duration (sec.) Port Event items
are related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero
Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.
NOTE
Warning e-mail messages will have sender given in the form:
Managed-Redundant-Switch-00000@Switch_Location
where Managed-Redundant-Switch-00000 is the default Switch Name, 00000 is TN-5500’s
serial number, and Switch_Location is the default Server Location.
Refer to the Basic Settings section to see how to modify Switch Name and Switch Location.
Email Setup

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies ToughNet Switch TN-5500 series and is the answer not in the manual?

Moxa Technologies ToughNet Switch TN-5500 series Specifications

General IconGeneral
BrandMoxa Technologies
ModelToughNet Switch TN-5500 series
CategorySwitch
LanguageEnglish

Related product manuals