RAW WATER CIRCUIT (open circuit)
Number of cylinders 16 16 16 16
Raw water pump: Inlet pressure, min. L bar -0.2 - -0.2 -
Raw water pump: Inlet pressure, max. L bar +0.5 - +0.5 -
Pressure loss in off-engine raw water sys-
tem, max.
L bar 1.0 - 1.0 -
LUBE OIL SYSTEM
Number of cylinders 16 16 16 16
Lube oil operating temperature before en-
gine, from
R °C 75 75 80 80
Lube oil operating temperature before en-
gine, to
R °C 80 80 85 85
Lube oil operating pressure before engine,
from
R bar 6.0 6.0 6.0 6.0
Lube oil operating pressure before engine,
to
R bar 7.0 7.0 7.0 7.0
Lube oil operating pressure (low idle)
(meas. point: before engine)
R bar N N N N
FUEL SYSTEM
Number of cylinders 16 16 16 16
Fuel pressure at engine supply connec-
tion, min. (when engine is starting)
L bar -0.3 -0.3 -0.3 -0.3
Fuel pressure at engine supply connec-
tion, min. (during engine operation)
L bar -0.3 -0.3 -0.3 -0.3
Fuel pressure at engine supply connection
(when engine is starting), max.
L bar +0.5 +0.5 +0.5 +0.5
Fuel supply flow rate, max. A liters/min 3.4 20 4.2 24
GENERAL OPERATING DATA
Number of cylinders 16 16 16 16
Firing speed, from R rpm 100 100 100 100
Firing speed, to R rpm 120 120 120 120
STARTING SYSTEM (electric)
Number of cylinders 16 16 16 16
Rated starter voltage (standard design) R V= 24 24 24 24
STARTING SYSTEM (with compressed air/hydraulic starter motor)
Number of cylinders 16 16 16 16
Starting-air pressure before starter motor,
min.
R bar 24* 24* 24* 24*
Starting-air pressure before starter, max. R bar 30 30 30 30
106 | Technical Data | MS150031/06E 2016-010
TIM-ID: 0000019124 - 001