7.8.3 Fuel system – Venting
Preconditions
Engine is stopped and starting disabled.
WARNING
Fuels are combustible and explosive.
Risk of fire and explosion!
Avoid open flames, electrical sparks and ignition sources.
Do not smoke.
Wear protective clothing, protective gloves, and safety glasses / facial protection.
Venting fuel system
1. Unlock fuel priming pump, unscrew handle.
2. Open vent plugs on filter head.
3. Operate the pump with the handle until bub-
ble-free fuel emerges at the vent plugs.
4. Close vent plugs on filter head.
170 | Fuel System | MS150031/06E 2016-010