3.13 16V 2000 M40A engine data: engine-mounted heat
exchanger, reference conditions: 25 °C intake air temperature
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated without changes (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine model 16V 2000
M40A
Application group 3B
Intake air temperature °C 25
Raw water inlet temperature °C 25
Barometric pressure mbar 1000
Site altitude above sea level m 100
POWER-RELATED DATA (power ratings are net brake power to ISO 3046)
Number of cylinders 16
Engine rated speed A rpm 1500
Continuous power ISO 3046 (10% overload capability) (design power DIN
6280, ISO 8528)
A kW 770
GENERAL CONDITIONS (for maximum power)
Number of cylinders 16
Intake air depression (new filter) A mbar 15
Intake air depression, max. L mbar 50
MODEL-RELATED DATA (basic design)
Number of cylinders 16
Cylinder configuration: V angle Degrees 90
Bore mm 130
Stroke mm 150
Cylinder displacement liter 1.99
Total displacement liter 31.84
Number of inlet valves per cylinder 2
Number of exhaust valves per cylinder 2
78 | Technical Data | MS150031/06E 2016-010