4.3 Putting the engine into operation after scheduled out-of-
service period
Preconditions
Engine is stopped and starting disabled.
Putting into operation
Item Action
Lube oil system Check engine oil level (→ Page 192).
Coolant circuit Check coolant level (→ Page 205).
Coolant circuit Preheat coolant with preheating unit.
Fuel prefilter Drain water (→ Page 176).
Battery-charging generator
drive
Check condition of drive belt (→ Page 212)
Engine Control System Switch master switch to ON;
Press illuminated pushbutton READY FOR OPERATION (→ Page 110).
LOP Press illuminated pushbutton LAMP TEST (→ Page 110).