Raw-water circuit (open circuit)
Number of cylinders 8
Raw water pump: Inlet pressure, min. L bar -0.2
Raw water pump: inlet pressure, max. L bar 0.5
Pressure loss in off-engine raw-water system, max. L bar 1.0
Lube oil system
Number of cylinders 8
Lube-oil operating temperature before engine, from R °C 70
Lube-oil operating temperature before engine, to R °C 75
Lube-oil operating pressure before engine, from R bar 5.6
Lube-oil operating pressure before engine, to R bar 6.1
Lube oil operating pressure (low idle) (meas. point: before engine) R bar 2.0
Fuel system
Number of cylinders 8
Fuel pressure at engine inlet connection, min. (when engine is starting) L bar -0.3
Fuel pressure at engine inlet connection, min. (when engine is running) L bar -0.3
Fuel pressure at engine inlet connection, max. (when engine is starting) L bar 0.5
Fuel supply flow, max. A liters/min 2.05
General operating data
Number of cylinders 8
Firing speed, from R rpm 100
Firing speed, to R rpm 120
Starter (electric)
Number of cylinders 8
Rated starter voltage (standard rating) R V= 24
Starter (with air/hydraulic starter motor)
Number of cylinders 8
Starting-air pressure before starter motor, min. R bar 18*
Starting-air pressure before starter motor, max. R bar 30
Capacities
Number of cylinders 8
Engine coolant, engine side (with cooling system) R Liters 70
Engine oil capacity, initial filling (standard oil system) (Option: max. operating
inclinations)
R Liters 65
Oil change quantity, max. (standard oil system) (Option: max. operating incli-
nations)
R Liters 60