7.22.3 Start interlock limit switch – Check
Preconditions
Engine is stopped and starting disabled.
Note: In its OFF position, the limit switch initiates start interlock, i.e. the engine cannot be started.
Start interlock limit switch –
Check
1. Check if switch housing (1) and cover plate
(3) are mounted and the switch (2) is in the
on position.
2. If switch housing (1) and/or cover plate (3)
is/are not mounted:
Secure cover plate (3) with screws.
Then install switch housing (1) with
screws, ensuring that the switch (2) is ac-
tuated by the cover plate (3).
3. If switch housing (1) and cover plate (3) are
mounted, but switch (2) is in the off position:
Make sure that the cover plate (3) at the
side of the switch (2) is not distorted.
Release switch housing (1) and fit it with
screws in a position providing that the
switch (2) is on.
If this is not possible, contact Service.