EasyManuals Logo

MTU 8V2000M40A User Manual

MTU 8V2000M40A
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #221 background imageLoading...
Page #221 background image
7.22.3 Start interlock limit switch – Check
Preconditions
Engine is stopped and starting disabled.
Note: In its OFF position, the limit switch initiates start interlock, i.e. the engine cannot be started.
Start interlock limit switch –
Check
1. Check if switch housing (1) and cover plate
(3) are mounted and the switch (2) is in the
on position.
2. If switch housing (1) and/or cover plate (3)
is/are not mounted:
Secure cover plate (3) with screws.
Then install switch housing (1) with
screws, ensuring that the switch (2) is ac-
tuated by the cover plate (3).
3. If switch housing (1) and cover plate (3) are
mounted, but switch (2) is in the off position:
Make sure that the cover plate (3) at the
side of the switch (2) is not distorted.
Release switch housing (1) and fit it with
screws in a position providing that the
switch (2) is on.
If this is not possible, contact Service.
MS150031/06E 2016-010 | Accessories for (Electronic) Engine Governor / Control System | 221
TIM-ID: 0000008444 - 006

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTU 8V2000M40A and is the answer not in the manual?

MTU 8V2000M40A Specifications

General IconGeneral
BrandMTU
Model8V2000M40A
CategoryEngine
LanguageEnglish

Related product manuals