4.5 Operational monitoring
DANGER
Rotating and moving engine parts.
Risk of crushing, danger of parts of the body being caught or pulled in!
Only run the engine at low power. Keep away from the engine's danger zone.
WARNING
High level of engine noise when the engine is running.
Risk of damage to hearing!
Wear ear protectors.
Operational monitoring
Item Measure
Engine under load,
engine at nominal speed
Visually inspect engine for leaks and general condition;
Check for abnormal running noises and vibration;
Check exhaust color (→ Page 131).
Fuel prefilter Check that contamination indicator position at the fuel prefilter is within the
permissible limit (→ Page 174).
Drain water and contaminants (→ Page 176).
Charge-air cooler Check drain line for water discharge and obstruction (→ Page 187).
Air filter Check signal ring position of service indicator (→ Page 190).
Replace air filter (→ Page 188) if the signal ring is completely visible in the
service indicator control window.
HT coolant pump Check relief bore for oil and coolant discharge and contamination
(→ Page 209).
Raw water pump Check relief bore for oil and coolant discharge and contamination
(→ Page 211).