4.2 Putting the engine into operation (out-of-service period > 3
months)
Preconditions
Engine is stopped and starting disabled.
MTU Fluids and Lubricants Specification (A001061/..) is available.
Putting the engine into operation (out-of-service period > 3 months)
Item Task
Engine Depreserve (→ MTU Fluids and Lubricants Specifications A001061/.. ).
Lube oil system Check oil level (→ Page 192).
Fuel prefilter Prime (→ Page 183).
Fuel prefilter, pressure
gauge
Align adjustable pointer with position of pressure indicator (→ Page 174).
Fuel system Vent (→ Page 170).
Raw-water pump (if located
above waterline)
Prime (approx. 3 to 4 liters).
Cooling system If engine is out of service for more than one year, change coolant
(→ Page 206).
Cooling system Check coolant level (→ Page 205).
Cooling system Preheat coolant with preheating unit.
ECU Check plug-in connections (→ Page 222).
Engine control system Switch ON.
Press READY FOR OPERATION button (→ Page 110).
LOP Press LAMP TEST button (→ Page 110).
112 | Operation | MS150031/06E 2016-010
TIM-ID: 0000002205 - 002