Fault
code
Alarm text Meaning Task
341 OPEN_LOAD CYL.
A1
Disconnection in wiring to sole-
noid valve cylinder A1;
Misfiring
1. Check wiring.
2. Contact Service.
342 OPEN_LOAD CYL.
A2
Disconnection in wiring to sole-
noid valve cylinder A2;
Misfiring
1. Check wiring.
2. Contact Service.
343 OPEN_LOAD CYL.
A3
Disconnection in wiring to sole-
noid valve cylinder A3;
Misfiring
1. Check wiring.
2. Contact Service.
344 OPEN_LOAD CYL.
A4
Disconnection in wiring to sole-
noid valve cylinder A4;
Misfiring
1. Check wiring.
2. Contact Service.
345 OPEN_LOAD CYL.
A5
Disconnection in wiring to sole-
noid valve cylinder A5;
Misfiring
1. Check wiring.
2. Contact Service.
346 OPEN_LOAD CYL.
A6
Disconnection in wiring to sole-
noid valve cylinder A6;
Misfiring
1. Check wiring.
2. Contact Service.
347 OPEN_LOAD CYL.
A7
Disconnection in wiring to sole-
noid valve cylinder A7;
Misfiring
1. Check wiring.
2. Contact Service.
348 OPEN_LOAD CYL.
A8
Disconnection in wiring to sole-
noid valve cylinder A8;
Misfiring
1. Check wiring.
2. Contact Service.
349 OPEN_LOAD CYL.
A9
Disconnection in wiring to sole-
noid valve cylinder A9;
Misfiring
1. Check wiring.
2. Contact Service.
350 OPEN_LOAD CYL.
A10
Disconnection in wiring to sole-
noid valve cylinder A10;
Misfiring
1. Check wiring.
2. Contact Service.
351 OPEN_LOAD CYL.
B1
Disconnection in wiring to sole-
noid valve cylinder B1;
Misfiring
1. Check wiring.
2. Contact Service.
352 OPEN_LOAD CYL.
B2
Disconnection in wiring to sole-
noid valve cylinder B2;
Misfiring
1. Check wiring.
2. Contact Service.
353 OPEN_LOAD CYL.
B3
Disconnection in wiring to sole-
noid valve cylinder B3;
Misfiring
1. Check wiring.
2. Contact Service.
354 OPEN_LOAD CYL.
B4
Disconnection in wiring to sole-
noid valve cylinder B4;
Misfiring
1. Check wiring.
2. Contact Service.
355 OPEN_LOAD CYL.
B5
Disconnection in wiring to sole-
noid valve cylinder B5;
Misfiring
1. Check wiring.
2. Contact Service.
356 OPEN_LOAD CYL.
B6
Disconnection in wiring to sole-
noid valve cylinder B6;
Misfiring
1. Check wiring.
2. Contact Service.
MS150031/06E 2016-010 | Troubleshooting | 129