Electronic Engine Monitoring Unit (EMU), optional
Functions:
Data processing logistics for analog and binary signals;
Interface for data transfer to CAN field bus for remote control and ship-side monitoring.
Electronic Gear Control Unit (GCU), ship-side wall-mounting
Functions:
Date processing logistics for gear coupling control;
Input/output signals as well as data transfer to CAN field bus for remote control and ship-side monitoring.
Monitoring in engine room
Engine control and monitoring unit (LOP)
Functions:
Alphanumeric, monochrome LCD display for monitoring of measured values as well as alarms when limits
are violated;
Pushbuttons for menu control and dimming unit;
Combined control and display elements for local engine/gear control;
Flashing light and horn for summary alarm in engine room;
Interface to CAN field bus for connected, communicating monitoring system components.
SOLAS – Fire protection specifications
All fuel lines with fuel pressure >1.8 bar are fitted with SOLAS-compliant covers as per MTU standard
MTN5233.
All oil lines with oil pressure >1.8 bar are fitted with SOLAS-compliant covers as per MTU standard
MTN5233.
Fuel system covers
20 | General Information | MS150031/06E 2016-010
TIM-ID: 0000002178 - 006

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTU 8V2000M40A and is the answer not in the manual?

MTU 8V2000M40A Specifications

General IconGeneral
BrandMTU
Model8V2000M40A
CategoryEngine
LanguageEnglish

Related product manuals