RAW WATER CIRCUIT (open circuit)
Number of cylinders 8
Raw water pump: Inlet pressure, min. L bar -0.2
Raw water pump: Inlet pressure, max. L bar +0.5
Pressure loss in external raw water system, max. L bar 1.0
LUBE OIL SYSTEM
Number of cylinders 8
Lube-oil operating temperature before engine, from R °C 75
Lube oil operating temperature before engine, to R °C 80
Lube oil operating pressure before engine, from R bar 5.6
Lube oil operating pressure before engine, to R bar 6.1
Lube oil operating pressure (low idle) (meas. point: before engine) R bar 2.0
FUEL SYSTEM
Number of cylinders 8
Fuel pressure at engine supply connection, min. (when engine is starting) L bar -0.3
Fuel pressure at supply connection to engine, min. (when engine is running) L bar -0.3
Fuel pressure at engine supply connection, max. (when engine is starting) L bar +0.5
Fuel supply flow, max. R liter/min 1.6
GENERAL OPERATING DATA
Number of cylinders 8
Firing speed, from R rpm 100
Firing speed, to R rpm 120
STARTING (electric)
Number of cylinders 8
Starter, rated voltage (standard design) R V= 24
STARTING SYSTEM (with air/hydraulic starter motor)
Number of cylinders 8
Starting air pressure before starter motor, min. R bar 18*
Starting air pressure before starter motor, max. R bar 30
CAPACITIES
Number of cylinders 8
Engine coolant, engine-side (with cooler) R liter 70*
Engine oil at initial filling (standard oil system) (Option: max. operating inclina-
tions)
R liter 65
Oil change quantity, max. (standard oil system) (Option: max. operating incli-
nations)
R liter 60