3-22 Chapter 3: Touch Screen Calibration – Windows (MT 7.12)
12. AdialogboxasksifyouwanttoTest,Accept,orCancelthis
calibration.SelectTest.
25409
You can test the linearization
by touching the 16 verification targets.
Do you want to proceed?
Yes No
5. SelectYestocontinue.
6. Touchthecenteroftheyellowtarget.
25410
7. Ifyousuccessfullytouchthetarget,itturnsgreen.Ifyourtouch
missesthetarget,thetargetturnsredandreturnsapercentage
errornumber.Ifthelinearizationisnotwithinacceptabletolerances
(nogreaterthan115%)thenrepeatthelinearizationprocess.
8. Performthe3Point
Calibrationprocedure.