4-2 Chapter 4: Touch Screen Calibration – Windows (MT 5.64, SR4)
Touch Calibration Procedures
UsetheTouchWareutilitiestoperformthefollowingprocedures:
• 2‐PointCalibration
• CursorStabilization
• 25‐PointLinearization
• RestoreDefaultsProcedure
TheTouchWareutilitiesareavailableontheNCRGoldDrivesfor
WinNT,Win2K,WinXPProandWinXPe.
Note: CustomerswhoarerunningaWindowsapplicationshould
always
useTouchWaretocalibrate.DonotbootintoDOSandrun
Microcal.
Applicationsoftwarecanpossiblygenerateadialogboxfromthe
TouchDriver,withthemessagethatthetouchscreenneedstobe
recalibrated.Ifthescreenappearstobeworkingnormally,thenthis
messagecanbeignored.Therewill
beacheckboxlabeled
Do not show this message again.Makesurethisboxis
checked.
Installing the Touch Driver
TheTouchdriverisincludedontheGoldImagefromNCR.However,
ifyouarebuildingyourownimagethenyoumustinstalltheTouch
drivermanuallyasfollows.
Note: IfaWindowsdriver(printer)isalreadyinstalledonCom1or
Com2priortoinstallingtheTouchWaredriveron
Com3,the
installationwillencounterproblems.
UninstalltheWindowsdriver
priortoinstallingtheTouchWaredriver.Theprintercanbere‐
installedafterTouchWareisinstalled.