Document Revision 1 Electra Elite IPK II
2 - 524 ISDN Compatibility
10-03-03 ETU Setup - CRC Multi-Frame (CRC4)
Setup and confirm the Basic Configuration data for each DTI ( )-U40 ETU. This program
determines whether or not the CRC Multi-Frame (CRC4) is used.
0 = Off (Default)
1 = On
10-03-04 ETU Setup - Layer 3 Timer Type
Setup and confirm the Basic Configuration data for each DTI ( )-U40 ETU. This program selects
the Layer 3 timer type (1~5). Each timer value of Layer 3 is set up for each type in Program
81-06 (T-Bus).
10-03-06 ETU Setup - Length of Cable
Setup and confirm the Basic Configuration data for each DTI ( )-U40 ETU. Select the length of
cable to be used.
0 = 0 ~ 40m (Default)
1 = 40 ~ 81m
2 = 81 ~ 122m
3 = 122 ~ 162m
4 = 162 ~ 200m
10-03-08 ETU Setup - Dial Sending Mode
Setup and confirm the Basic Configuration data for each DTI ( )-U40 ETU. Select either enblock
or overlap sending.
0 = Enblock Sending
1 = Overlap Sending (Default)
10-03-09 ETU Setup - Dial Information Element
Setup and confirm the Basic Configuration data for each DTI ( )-U40 ETU. If Overlap Sending is
selected in Program 10-03-08, select either Keypad Facility (0) or Called Party Number (1) for
the dial information element.
21-12-01 ISDN Calling Party Number Setup for Trunks - Calling Party Number Data
Assign Calling Party Numbers for each trunk (maximum 16 digits per entry).
After the above programming is complete a reset of the BRT (4)-U20 ETU is required.
14-05-01 Trunk Groups - Trunk Group Number
Assign trunks to Trunk Groups, also assign the outbound priority for trunks within the group.
21-01-03 System Options for Outgoing Calls - Trunk Interdigit Time (External)
The time the system waits for the timer to expire before placing the call in a talk state (default: 5