Document Revision 1 Electra Elite IPK II
2 - 610 Music on Hold
10-04-01 Music on Hold Setup - Music on Hold Source Selection
Determine whether the system should use No Tone (0), External (1) Music Source, or Internal
Service Tone (2). If set to ‘1’, Program 14-08-01 must be set to ‘0’ or ‘1’.
10-04-03 Music on Hold Setup - Audio Gain Setup
Set the Music on Hold audio gain (1~63).
14-08-01 Music on Hold Source for Trunks
For each trunk, set the Music on Hold source.
0 = Internal/External MOH
1 = Customer Provided Source Connected to BGM Port
2 = Customer Provided Source Connected to ACI Port
14-08-02 Music on Hold Source Port Number
If the MOH type is “2” in 14-08-01, for each trunk enter the ACI source port number (1~96).
33-01-01 ACI Port Type Setup
If ACI software port is designated for MOH in 14-08-01, set port’s function to 1 (input).
80-01-01 Service Tone Setup, Music On Hold Tone, Service Tone 64
If required, change the tone heard by the user when placed on hold when Program 10-04-01 set
to "2".
When Using a PGD(2)-U10 ADP:
10-03-01 ETU Setup - Terminal Type
If a PGD(2)-U10 ADP is used for the external music source, the module will automatically be
assigned type ‘9’ if the jumper straps in the module have been set prior to connecting it to the
system. If another type has been assigned, disconnect the PGD(2)-U10 ADP from the system,
delete the type setting, and, with the jumper straps positioned correctly in the PGD(2)-U10
ADP
, reconnect the module to the system. Refer to the Electra Elite IPK II System Hardware
Manual for the jumper strap settings.