Document Revision 1 Electra Elite IPK II
2 - 660 PC Programming
Connecting
As can be seen in Figure 2-7 PC Programming Overview, three connection types are available to
PCPro/WebPro.
If using PCPro, a user can connect directly, remotely using a modem or via LAN. A connection with the
KTS is made via the “Connection Dialog” within the application. (Refer to Figure 2-8 PCPro Connection
Dialog Box.)
J
Direct connections are established using the RS232 serial port (COM Port 1) on the side of the
KTS.
J
Modem (remote) connections are established via the internal CPU modem. You need to dial in to
an extension on the KTS and redirect that extension to the internal modem.
J
IP (LAN) connections are established via the Ethernet connector on the CPU card.
Figure 2-8 PCPro Connection Dialog Box
Set up the COM port to match
the KTS (PRG 10-21-02 on the
KTS)
IP address of the KTS (PRG
10-12-01 on the KTS)
User Name/Password is taken
from PRG 90-02 on the KTS