Digital Trunk Clocking Examples:
If multiple PRIs exist, the first one that synchronized with the carrier is chosen. In this example, the
PRI in slot02 was the first to synchronize with the carrier; therefore, it is the PLO synchronization
source.
Main KSU
Exp. KSU
PRIPRI
Figure 1-7 Digital Trunk Clocking Example 1
If there are multiple PRIs and the one being used for the source goes down, the system begins to
count forward in slot numbers looking for the next available PRI. In this example, the PRI in slot02
went down, so the system now begins looking forward in slot numbers for the next PRI to use as the
clock source.
Main KSU
Exp. KSU
PRIPRI
Figure 1-8 Digital Trunk Clocking Example 2
In this example, the PRI in slot06 (SL1000) slot05 (SL1100) was the first to synchronize with the
carrier and became the PLO synchronization source. The PRI in slot06 (SL1000) slot05 (SL1100) then
went down and the system began looking forward in slot numbers to find the next PLO source. In this
case, the PRI in slot02 was the next source because after it looks through the rest of the slots in the
system, it starts over with slot01.
Main KSU
Exp. KSU
PRIPRI
Figure 1-9 Digital Trunk Clocking Example 3
In this example, there are multiple T1 circuits in the system. There can only be one T1 circuit assigned
as EXTERNAL in the system, so the T1 assigned as EXTERNAL is the PLO synchronization source.
SL1000/SL1100
ISSUE 2.0
1-194
Digital Trunk Clocking