Timer
Class 0
Timer Class
1~15
Title Comment
24-01-04 20-31-13 Exclusive Hold Recall Callback Time An Exclusive Hold Recall rings an extension for this
time. If not picked up, the call goes back on Non ex-
clusive Hold. Station Timer Class is referred by held
call.
24-01-06 20-31-14 Park Hold Time - Normal A call left parked longer than this time recalls the ex-
tension that initially parked it. Trunk or Station Timer
Class is referred by held call.
24-02-03 20-31-15 Delayed Call Forwarding Time If activated at an extension, No Answer Call For-
warding occurs after this time. Station Timer Class is
referred by the station sets No Answer Call Forward.
24-02-04 20-31-16 Transfer Recall Time A transferred call recalls to the extension that initially
transferred it after this time. Station Timer Class is
referred by transferred call.
25-07-02 20-31-17 VRS/DISA No Answer Time After this time expires, the call follows the program-
med Ring No Answer routing (PRG 25-03 and PRG
25-04-01). Trunk Timer Class is referred.
25-07-03 20-31-18 Disconnect after VRS/DISA Re-trans-
fer to IRG
Disconnect after re-transfer to Incoming Ring Group.
Trunk Timer Class is referred.
25-07-07 20-31-19 Long Conversation Warning Tone
Time
Determine the time trunk-to-trunk conversation can
talk before the Long Conversation tone is heard.
Trunk Timer Class is referred.
25-07-08 20-31-20 Long Conversation Disconnect Time This timer determines how long the system waits be-
fore disconnecting a trunk-to-trunk conversation call
after the Long Conversation tone is heard. Trunk
Timer Class is referred.
25-07-09 20-31-21 DISA Internal Paging Time This is the maximum length of an Internal Page
placed by a DISA caller. If the Page continues lon-
ger than this time, the system terminates the DISA
call. Trunk Timer Class is referred.
25-07-10 20-31-22 DISA External Paging Time This is the maximum length of an External Page
placed by a DISA caller. If the Page continues lon-
ger than this time, the system terminates the DISA
call. Trunk Timer Class is referred.
31-01-02 20-31-23 Page Announcement Duration This timer sets the maximum length of External
Page announcements. Station or Trunk Timer Class
is referred by the caller makes announcement.
Conditions
• Timer Classes are used for CAR/VE also.
• When Timer Class is set to 0 it uses the system-wide timers.
• Both system-wide timers (Timer Class 0) and Timer Class timers (Timer Class 1~15) can be used in
the same system.
Default Settings
Timer Class set to 0 for all trunks and extensions.
System Availability
Terminals
All Multiline Terminals
SL1000/SL1100
ISSUE 2.0
1-260
Flexible Timeouts
F