EasyManuals Logo

Neoway N11 V2 User Manual

Neoway N11 V2
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
N11 V2
AT Command Manual
Copyright © Neoway Technology Co., Ltd
52
1: Not receive the message type defined by <mids> and <dcss>.
<mids>: Char type, for example, 0, 1, 5, 320 to 478, 922. All possible combination
of CBM message IDs (refer to <mid>).
<dcss>: Char type, for example 0 to 3, 5. All possible combination of CBM data
encoding plans (refer to <dcs>) (the default value is empty character string)
Return Value
See the Example.
Example
AT+CSCB=0,"2","2"
OK
Enable channel 2 and
disable other channels.
AT+CSCB?
+CSCB:
1,"50,4383,4356,4370,60","0,1,2,3,4,5,6,7,8,9,10,11,
12,13,14,32,33,34,35,36,15"
OK
Query current CBM type
channel. Channel 2 is
enabled.
AT+CSCB=?
+CSCB: (0,1)
OK
Query the value range of
broadcast message
status.
Remarks
N/A