EN
11 – English
TABLE 22 - Led’s on the control unit’s buttons
L1 Led Description
Off Correct during normal operation
On Lit for 10 seconds means that the transmitter memorisation is being performed
Itashes • Function programming in progress
• Radio transmitter cancellation or diagnostics
L2 Led Description
Off Indicates slow “motor speed” during normal operation
On Indicates fast “motor speed” during normal operation
Itashes • Function programming in progress
•IfitashestogetherwithL3,itmeansthatittheusermustcarryoutthegateopeningandclosingpositions
recognitionphase(refertoParagraph“4.3Recognitionlengthoftheleaf”)
L3 Led Description
Off Indicates “Automatic Closing” is active during normal operation
On During normal operation the device indicates “Automatic Closing” is not active
Itashes • Function programming in progress
•IfitashestogetherwithL2,itmeansthatittheusermustcarryoutthegateopeningandclosingpositions
recognitionphase(refertoParagraph“4.3Recognitionlengthoftheleaf”)
7.8 - Accessories: PS124
Road400 is also available with the PS124 - 1.2 Ah back-up battery with incorporated charger, as an optional accessory. To connect the back-up battery, see
Figure 28.