6 Operating status messages
BU 0250 en-3021 169
12.1 Limit moto./Customer
"Drive switch-off limit"
The drive switch-off limit (P534 [-01]) has triggered.
• Reduce load on motor
• Set higher value in (P534 [-01]).
12.2 Limit gen.
"Generator switch-off limit"
The generator switch-off limit (P534 [-02]) has triggered.
• Reduce load on motor
• Set higher value in (P534 [-02]).
12.3 Torque limit
Limit from potentiometer or setpoint source has switched off.
P400 = 12
12.4 Current limit
Limit from potentiometer or setpoint source has switched off.
P400 = 14
12.5 Load monitor
Switch-off due to overshooting or undershooting of
permissible load torques ((P525) … (P529)) for the time set
in (P528).
• Adjust load.
• Change limit values ((P525) ... (P527)).
• Increase delay time (P528).
• Change monitoring mode (P529).
12.8 AI minimum
„Analogue In minimum“
Switch-off due to undershooting of the 0% adjustment value
(P402) with setting (P401) "0-10V with switch-off on error 1"
or "....2"
12.9 AI maximum
„Analogue In maximum“
Switch-off due to overshooting of the 100% adjustment
value (P402) with setting (P401) "0-10V with switch-off on
error 1" or "....2"
Pos: 588 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Fehler E013 [ SK 200E ... SK 5xxE] @ 2\mod_13474542712 18_388.docx @ 46751 @ @ 1
E013
13.0 Encoder error
No signal from encoder
• Check 5V sensor if present.
• Check supply voltage of encoder.
13.1 Speed slip error
"Speed slip error"
The slip speed error limit was reached.
• Increase setting in P327.
13.2 Shut-down monitoring
The slip error monitoring has triggered; the motor could not
follow the setpoint.
• Check motor data P201-P209! (Important for the
current controller)
• Check motor circuit.
• In servo mode, check the encoder setting P300 and
check the following
• Increase setting value for torque limit in P112.
• Increase setting value for current limit in P536.
• Check deceleration time P103 and extend if
necessary
13.5 Reserved
Error message for POSICON see supplementary
instructions
13.6 Reserved
Error message for POSICON see supplementary
instructions
Pos: 589 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Fehler E014 "r eserviert" [SK 200E ... SK 5xxE/SK 500P] @ 2\mod_134 7454273854_388.doc x @ 46776 @ @ 1
E014
--- Reserved
Error message for POSICON see supplementary
instructions
Pos: 590 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Fehler E015 [ SK 180E ... SK 5xxE] @ 2\mod_1347454278051_3 88.docx @ 46801 @ @ 1
E015
--- Reserved
Pos: 591 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Fehler E016 [ SK 135E ... SK 5xxE, SK xxxE-FDS] @ 2\mod_13474542806 25_388.docx @ 46826 @ @ 1
E016
16.0 Motor phase error
A motor phase is not connected.
• Check P539
• Check motor connection