Introduction
2‐10
P/N 397189E
E 2006 Nordson Corporation
BM200_EASY_GEAR
Button Two‐hand Control and Pneumatic Switch
Used to manually control the heating punch when the drum is being
changed.
WARNING: The two‐hand control may only be operated by one person
using both hands!
The pneumatic switch lights up green when the drum is inserted.
Control System
On the control system, values and parameters are set, and operating modes
and faults are displayed.
Refer to manual for the Control System used.
Key Switch Remote / Local and Indication Lamp Remote
When set to Remote, the system is not controlled by the internal control
system but via the interface Profibus (Option).
Main Switch
The main switch is used to switch the system on and off.
Position 0/OFF = System is switched off.
Position I/ON = System is switched on.
Padlocks can be used to protect the main switch from unauthorized access.
Black Main Switch (Special Model)
Systems with a black main switch are normally supplied with power by a
higher‐ranking system; the higher‐ranking main switch is on that system. The
black main switch does not perform the EMERGENCY OFF function.
Connected components can still be switched on!
Electrical Cabinet Ventilation
Air Filter / Fan with Filter
Electrical cabinet ventilation reduces the temperature inside of the electrical
cabinet. It must be serviced regularly. Refer to Maintenance.