Maintenance
5‐5
P/N 397189E
E 2006 Nordson Corporation
BM200_EASY_GEAR
Compressed Air Filter
The compressed air filter dehydrates and cleans the compressed air.
Draining Condensate
Drain condensate before it reaches a level approx. 10 mm below the filter
disk.
To do this, open the condensate drain valve (7).
Cleaning Filter Element
Under normal conditions, clean filter element (5) approx. every three months.
Clean sooner if compressed air filter outlet pressure falls.
1. Stop compressed air supply and release residual pressure by opening
the condensate drain valve (7).
2. Unscrew condensate collector (6).
3. Unscrew filter element (5) by turning to the left.
4. Rinse filter element (5) with suitable cleaning agent. Then blow out from
the inside. The condensate collector (6) may not come into contact with
the cleaning agent!
5. Clean condensate collector (6) if necessary. Use only water!
6. Reassemble compressed air filter.