Technical Data
8‐2
P/N 397189E
E 2006 Nordson Corporation
BM200_EASY_GEAR
Motors / Speeds
Motor Motor / gear pump speed setting range
3‐phase AC motor with helical gear 1 to 100 min
‐1
To prevent excessive wear, the motor/pump speed
should not continuously fall below 5 min
‐1
(rpm) or
continuously exceed 80 min
‐1
(rpm).
Temperatures and Thermostats
Temperatures System / components ° C °F
Min. ambient temperature - 10 50
Max. ambient temperature - 40 104
Min. operating temperature - 50 122
Adjustable operating temperatures
CAUTION: When setting the
temperature, the temperature
prescribed by the hot melt adhesive
manufacturer is decisive. The
maximum operating temperature for the
product and heated components
described here may not be exceeded.
Depending on the heating channel max. . . . 230 446
Overtemperature shutdown by
thermostat
Permissible thermostats
230 ° C 450 ° F
177 ° C 350 ° F
150 ° C 300 ° F
Replacing thermostat: refer to Repair
Air Consumption
Per cycle (melting plate down and up) Approx. 600 l
Exhaust Hood
Nominal air quantity (recommendation) 510 m
3
/h
Pressure loss at nominal air quantity Approx. 180 Pa
Connecting sleeve ∅ 150 mm