Operation
4‐1
P/N 397189E
E 2006 Nordson Corporation
BM200_EASY_GEAR
Section 4
Operation
WARNING: Allow only qualified personnel to perform the following tasks.
Observe and follow the safety instructions in this document and all other
related documentation.
Initial Startup
NOTE: Some of the following tasks are described in detail in the subsequent
text.
1. Ensure that the switch rod is set to the drum height.
2. Set pneumatic switch to 0.
3. Set main switch to I/ON.
4. Control system: Set values and parameters.
5. Set week timer, if present.
6. Insert drum.
7. Pre‐select motor and switch on.
8. Set motor speed on control system to achieve desired output quantity.
With option Pressure Control: Set the setpoint pressure instead of the
motor speed.
NOTE: To prevent excessive wear, the motor/pump speed should not
continuously fall below 5 min
‐1
(rpm) or continuously exceed 80 min
‐1
(rpm).
9. Optimize settings and record in settings record form.
NOTE: All system functions were tested before the system left the factory.
Special test material was used. There may be residue from this material on
the melting plate, in the pump, etc. To remove such residue, melt and feed
several kilograms of material before starting production.