WARNING: Hot! Risk of burns. Wear heat‐protective gloves.
1. Heat heating punch to operating temperature.
2. Aerate drum.
3. Set pneumatic switch to Raise until the heating punch exits the drum.
4. Set pneumatic switch to 0/Stop.
5. Place a clean, hard, heat‐resistant surface (e.g. metal plate) on the drum
under the melting plate.
6. Set pneumatic switch to Lower until the melting plate reaches the resting
surface.
7. Set pneumatic switch to 0/Stop.
WARNING: Risk of electrical shock. Failure to observe may result in
personal injury, death, or equipment damage.
8. Disconnect the system from the line voltage.
9. Remove cover (1).