Operation
4‐6
P/N 397189E
E 2006 Nordson Corporation
BM200_EASY_GEAR
Switching System ON/OFF
NOTE: Before initial startup, read and observe the instructions in Initial
Startup. Start up only as described under Initial Startup.
NOTE: The main switch must be set to I/ON (switched on) when using the
week timer (accessory). Additional information on the week timer can be
found in the manual Week Timer.
NOTE: When external system release via interface XS2 is used, the main
switch must be set to I/ON (switched on).
Daily Startup
NOTE: Do not operate Nordson pumps without material. Before switching on
motor, ensure that a drum that is not empty is in the system and that the
heating punch has contact with the material.
NOTE: To prevent excessive wear, the motor/pump speed should not
continuously fall below 5 min
‐1
(rpm) or continuously exceed 80 min
‐1
(rpm).
1. Set main switch to I/ON.
2. Set pneumatic switch to Lower.
3. Wait until system is ready.
4. Pre‐select motor.
5. Switch on motor.
Daily Switchoff
1. Set main switch to 0/OFF and protect from unauthorized access with
padlocks if necessary.
2. Set pneumatic switch to Stop.
3. Perform daily maintenance.