Installation
3‐5
P/N 397189E
E 2006 Nordson Corporation
BM200_EASY_GEAR
Electrical Connections
WARNING: Risk of electrical shock. Failure to observe may result in
personal injury, death, or equipment damage.
Laying Cable
WARNING: Use only temperature resistant cable in the heating part of the
system. Ensure that cables do not touch rotating and/or hot parts. Do not
pinch cables and check regularly for damage. Replace damaged cables
immediately!
Line Voltage
WARNING: Operate only with the line voltage stated on the ID plate.
NOTE: Permitted deviation from the rated line voltage is +5% / ‐10%.
NOTE: The power connection cable must have a cross‐section matching the
power consumption P
max
. (Refer to ID Plate).
Power Supply
The mains terminals are located in the electrical cabinet. Refer to Wiring
Diagram for connecting arrangement.
Hose Receptacle(s)
For electrical connection values, refer to Technical Data.
Operating with Assembly Handguns
For applications with assembly handguns that switch the motor via the
heated hose, the bridge XLS1: 1 ‐ 2 (Refer to Wiring Diagram) must be
removed.
Pilot Voltage / Tach Generator
For automatic mode, pilot voltage must be connected to XS5. The pilot
voltage can be supplied e.g. by a tach generator (accessory) driven by the
parent machine.
CAUTION: The pilot voltage may not exceed 160 V
DC
. Failure to observe
will result in damage to succeeding components.