Technical Data
8‐1
P/N 397189E
E 2006 Nordson Corporation
BM200_EASY_GEAR
Section 8
Technical Data
General Data
Type of heating Cast‐in electrical resistance heating elements
Temperature sensor Ni 120
Degree of protection IP 54
Heatup time 30 to 60 minutes, depending on system, material
used and ambient temperature
Noise emission < 72 dBA
Electrical Specifications
WARNING: Operate only at the operating voltage shown on the ID plate.
Operating voltage
Refer to ID plate
Operating voltage frequency 50/60 Hz
Fuse rating Refer to ID plate
Power consumption P Refer to ID plate
Power consumption P
max
Refer to ID plate
Load per hose receptacle (2 channels) Max. 1800 Watt
Max. pilot voltage (input voltage) 160 V
DC
The pilot voltage may not exceed 160 V
DC
. Failure
to observe will result in damage to succeeding
components.
or 0 ‐ 10 V
The pilot voltage must be adjusted (Refer to manual
Control System).