Installation
3‐8
P/N 397189E
E 2006 Nordson Corporation
BM200_EASY_GEAR
Pneumatic Connection
Connect dry, clean and non‐lubricated compressed air (2). Set air pressure
for pneumatic cylinder to approx. 5 bar (0.5 MPa / 72.5 psi) on the pressure
controller (1). The setting can be modified according to the material
processed (max. 7.5 bar / 0.75 MPa / 109 ps).
The air pressure in the pneumatic cylinders is limited to 7.5 bar (0.75 MPa /
109 psi) by a pressure restrictor valve.
Preparing for Changeover System
The DIP switches S 8.1 and S 8.2 of the CS 20 control system's temperature
control panel board must be set to OFF (no leading channel) in changeover
systems. Refer to separate manual for control system.
Reducing Heating Punch Lifting Speed
NOTE: The lifting speed need only be reduced if the heating punch often lifts
the drum as it moves up.
1. Remove protective plate (1) from pneumatics.
2. Turn throttle screw (2) clockwise slightly with a screwdriver. The correct
setting must be determined by trial and error.
3. Attach protective plate again.