Installing Heated Hoses
WARNING: Hot! Risk of burns. Wear heat‐protective gloves.
Laying Hoses
Guide hose through the hose guide. The hose connection is located on the
heating punch.
Connecting
If cold material can be found in the hose connection (1) and/or hose fitting
(2), these components must be heated until the material softens (approx.
80 _C, 176 _F).
1. First connect the hose (3) electrically to the unit. For more than one hose:
Every hose connection is allocated to a corresponding receptacle. Do not
mistakenly exchange!
2. Heat the system and hose to approx. 80 _C (176 _F).
3. Screw the heated hose onto the unit.
NOTE: Close unused hose connections with Nordson port plugs.
Disconnecting
WARNING: System and material pressurized. Relieve system pressure
before disconnecting heated hoses. Failure to observe can result in serious
burns.
Relieving Pressure
1. Set motor speed to 0 min‐1 (rpm); switch off motor(s).
2. Place a container under the nozzle(s) of the application head/assembly
handgun.
3. Activate the application head / assembly handgun electrically or
manually. Repeat this procedure until no more material flows out.
4. Re‐use the material or dispose of properly according to local regulations.
Second Open‐jawed Wrench
Use a second open‐jawed wrench when connecting and disconnecting the
heated hose. This prevents the unit's hose connection from turning.