Installation
3‐9
P/N 397189E
E 2006 Nordson Corporation
BM200_EASY_GEAR
Accessories
The following components can also be installed later as accessories:
Light Tower
The light tower must be screwed onto the electrical cabinet. It must be
connected to terminal XLWT according to the Wiring Diagram.
Week Timer
The week timer must be installed in the electrical cabinet. To do this, remove
clamp XLWZ and install the week timer in its place. Wire according to Wiring
Diagram.
Tach Generator
It is connected to receptacle XS 5.
Also refer to Wiring Diagram and manual Tach Generator.
NOTE: The pilot voltage produced by the tach generator must be adjusted
(Refer to manual for the control system used).
CAUTION: The pilot voltage may not exceed 160 V
DC
. Failure to observe
will result in damage to succeeding components.
Transformer
Systems designed for operating voltage of 400VAC, 3 Ph Y can be operated
at 200 or 240 VAC with the transformer.