EasyManua.ls Logo

Oceanic GEO - BACKLIGHT

Oceanic GEO
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
A single short beep (which cannot be disabled) is emitted for the following -
• Upon completion of a Hot Swap battery change.
• Change from Delayed to Full Violation 5 minutes after the dive.
3 short beeps (which cannot be disabled) are emitted for the following -
• NORM/GAUG Ascent Rate is 51 to 60 FPM (15.1 to 18 MPM) when deeper
than 60 FT (18 M), or 26 to 30 FPM (7.5 to 9 MPM) at 60 FT (18 M) and
shallower.
• FREE Elapsed Dive Time Alarm (3 beeps every 30 seconds if set On).
• FREE Depth Alarms 1/2/3 (set sequentially deeper) - each 3 beeps 3 times.
• FREE TLBG Alarm (Caution zone, 4 segments) - 3 beeps 3 times.
• Entry into Deco during a FREE Dive (Permanent Violation) - 3 beeps 3 times.
• Free Dive Mode Countdown Timer reaches 0:00 - each 3 beeps 3 times.
During the following NORM Dive situations, the 10 second continuous tone will be
followed by a 5 second steady beep that will not turn off when acknowledged -
• Ascending above a required Decompression Ceiling Stop Depth for more
than 5 minutes (referred to as a Delayed Violation).
• Decompression requires a Ceiling Stop Depth of 70 FT (21 M) or deeper.
• Being on the Surface for 5 minutes after a Conditional Violation (Permanent
Violation).
BACKLIGHT
To activate the Backlight - press the L button.
• The Backlight will activate and illuminate the display for button depression
time (10 seconds maximum) plus the user set Duration time of 0, 5, or 10
seconds, for a maximum of 20 seconds.
• Press the button again to activate as desired.

Table of Contents