SET NORM/GAUG SAMPLING RATE, information includes
(Fig. 52):
> Graphics SAMP and SEC
> Set Point (seconds), flashing, with TIME icon.
• Pressing and releasing the S button momentarily (< 2
seconds) will step through the Set Points of 2, 15, 30, 60
(seconds).
• Pressing and releasing the A button (< 2 seconds) will
accept the setting and/or advance to the SET U screen.
• Depressing and holding the M button for 2 seconds or if
no button is pressed for a period of 2 minutes operation
will revert to the NORM or GAUG SURF MAIN screen.
SERIAL NUMBER (SN)
• Depressing the A and S buttons simultaneously for 8
seconds while viewing the NORM (or GAUG) SURF MAIN
screen will access the SN screen displaying (Fig. 53):
> Graphic SN
> Factory programmed Serial Number of the GEO.
> Firmware revision number (e.g., graphic r1A).
• Depressing the A and S buttons simultaneously for 2
seconds will revert to the NORM (or GAUG) SURF MAIN
screen.
Fig. 52 - SET
SAMPLING RATE
Fig. 53 - SERIAL
NUMBER