44473001TH Rev.1
184 /
Oki Data CONFIDENTIAL
7. TROUBLESHOOTING PROCEDURES
Warning
No. Category
PJL Status
Code
Error Warning Description
1 Warning 10082 (Y)
10083 (M)
10084 (C)
10081 (K)
1
2
3
4
5
%COLOR% Toner Low
Please see Help for details.
Toner amount is low.
Moreover, when set
as "Admin Setup"-
"Management"-"System
Setup"-"Near Life
LED"=Disable, Alarm
LED is switched off.
%COLOR%
Y
M
C
K
2 Warning 10959 (Y)
10960 (M)
10961 (C)
10958 (K)
1
2
3
4
5
Please install new K Toner
Cartridge.
Please see Help for details.
This warning is displayed
at Cover Open/Close
or Power OFF/ON after
a waste-toner full error
(no.142) occurs. (occur
in Black only.) Displayed
in a combination of other
message in the first line.
As long as this warning is
being displayed, a waste
toner full error occurs ,
the printer shifts to Offline
and stops each time it has
printed about 50 copies.
%COLOR%
K
3 Warning 10925 (Y)
10926 (M)
10927 (C)
10924 (K)
1
2
3
4
5
Please install new %COLOR%
Toner Cartridge.
Please see Help for details.
It shows the toner
cartridge of authorized
3rd party. (RFID Licensed
to 3rd party)
%COLOR%
Y
M
C
K
No. Category
PJL Status
Code
Error Warning Description
4 Warning 10955 (Y)
10956 (M)
10957 (C)
10954 (K)
1
2
3
4
5
%COLOR% Toner Cartridge
Region Mismatch
Please see Help for details.
The Region ID of toner
cartridge is not proper to
the distribution channel.
%COLOR%
Y
M
C
K
5 Warning 10951 (Y)
10952 (M)
10953 (C)
10950 (K)
1
2
3
4
5
Non Genuine %COLOR% Toner
Cartridge
Please see Help for details.
The chip of RFID is not
compatible.
%COLOR%
Y
M
C
K
6 Warning 10077 (Y)
10078 (M)
10079 (C)
10076 (K)
1
2
3
4
5
Image Drum Unit Near Life
Please see Help for details.
The life of the drum
(warning). Displayed in
a combination of other
message in the first line.
The printer stops at the
point when it reaches the
drum life (Shifts to error,
OFF-LINE.)
Moreover, when set
as "Admin Setup"-
"Management"-"System
Setup"-"Near Life
LED"=Disable, Alarm
LED is switched off.
%COLOR%
Y
M
C
K
*In FX750, there is not
%COLOR% information
because 4 image drum
unit is one body model.