5238-E P-340
SECTION 15 APPENDIX
M124 STM time over check ON
M125 STM time over check OFF
M126 Additional air blower 3 OFF
M127 Additional air blower 3 ON
M128 Tailstock swing retract
M129 Tailstock swing advance
M130 Chucking error detecting air output OFF
M131 Chucking error detecting air output ON
M132 Chucking error detection OFF
M133 Chucking error detection ON
M134 Z-axis thrust monitoring OFF
M135 Z-axis thrust monitoring ON
M136 Shape designation for compound fixed cycle
M137 Touch setter interlock release ON
M138 Touch setter interlock release OFF
M139 Lead machining function - learning operation
M140 Tapping cycle M-tool constant rotation answer ignored
M141 C-axis clamp or not selection
M142 Coolant pressure, low
M143 Coolant pressure, high
M144 Additional coolant 1 OFF
M145 Additional coolant 1 ON
M146 C-axis unclamp
M147 C-axis clamp
M148 Pick-off spindle start, CW
M149 Pick-off spindle start, CCW
M150 Synchronized rotation OFF
M151 Synchronized rotation ON
M152 M-tool spindle interlock ON
M153 M-tool spindle interlock OFF
M154
Additional air blower 2 OFF
(air blower for gauging)
M155
Additional air blower 2 ON
(air blower for gauging)
M156 Center work interlock OFF
M157 Center work interlock ON
M158 Lead machining function - synchronized operation OFF
M159 Lead machining function - synchronized operation ON
M160 Cancel of M161
M161 Feedrate override fix (100%)
M162 Cancel of M163
M163 M-tool spindle speed override fix (100%)
M164 Cancel of M165
M165 Ignoring slide hold and single block
M Code Contents