Specifications
65
Table 15 Scanner setup chart for smaller pipes
Pipe outside diameter
Tail
setting
Probe-
holder
position
Number of links per side
in. mm Half Male Female
0.84 to 0.86 21.3 to 21.8 1
Retracted
1
0.86 to 0.89 21.8 to 22.6 1.5
0.89 to 0.91 22.6 to 23.1 2
0.91 to 0.93 23.1 to 23.6 2.5
0.93 to 0.95 23.6 to 24.1 3
0.95 to 0.99 24.1 to 25.1 3.5
0.99 to 1.05 25.1 to 26.7 4 Centered
1.05 to 1.10 26.7 to 27.9 1
Extended 1 1
1.10 to 1.15 27.9 to 29.2 2
1.15 to 1.21 29.2 to 30.7 3
1.21 to 1.28 30.7 to 32.5 4
1.28 to 1.36 32.5 to 34.5 1
Extended 1 2
1.36 to 1.43 34.5 to 36.3 2
1.43 to 1.49 36.3 to 37.8 3
1.49 to 1.56 37.8 to 39.6 4
1.56 to 1.63 39.6 to 41.4 1
Extended 1 1 2
1.63 to 1.70 41.4 to 432 2
1.70 to 1.76 43.2 to 44.7 3
1.76 to 1.88 44.7 to 47.8 4
1.88 to 1.96 47.8 to 49.8 1
Extended 2 3
1.96 to 2.03 49.8 to 51.6 2
2.03 to 2.09 51.6 to 53.1 3
2.09 to 2.16 53.1 to 54.9 4
2.16 to 2.24 54.9 to 56.9 1
Extended 1 2 3
2.24 to 2.30 56.9 to 58.4 2
2.30 to 2.37 58.4 to 60.2 3
2.37 to 2.5 60.2 to 63.5 4

Table of Contents