1191
CS/CJ/NSJ Series Instructions Reference Manual (W474)
4. Instruction Execution Times and Number of Steps
4-2 CJ1 CPU Unit Instruction Execution Times and Number of Steps
4
4-2-23 Network Instructions
4-2-23 Network Instructions
4-2-24 File Memory Instructions
4-2-25 Display Instructions
RECEIVE VIA
SERIAL COM-
MUNICA-
TIONS UNIT
RXDU 4 131 131 200.8 211.8 206.8 --- Storing 1 byte
CHANGE
SERIAL PORT
SETUP
STUP 3 341.2 341.2 400.0 504.7 524.7 440.4 Addressed to
COM port on
CPU Unit
Instruction Mne-
monic
Length
(steps)
ON execution time (µs) Conditions
CJ1H
CPU6@
H-R
CJ1H
CPU6@
H
CJ1G
CPU4@
H
CJ1M
CPU12/13/
22/23
CJ1M
CPU11/
21
CJ1G
CPU4@
NETWORK
SEND
SEND 4 84.4 84.4 123.9 141.6 195.0 123.9 ---
NETWORK
RECEIVE
RECV 4 85.4 85.4 124.7 142.3 196.7 124.7 ---
DELIVER COM-
MAND
CMND 4 106.8 106.8 136.8 167.7 226.7 136.8 ---
EXPLICIT MES-
SAGE SEND
EXPLT 4 127.6 127.6 190.0 217.0 238.0 --- ---
EXPLICIT GET
ATT RI BU TE
EGATR 4 123.9 123.9 185.0 210.0 232.7 --- ---
EXPLICIT SET
ATT RI BU TE
ESATR 3 110.0 110.0 164.4 188.3 210.3 --- ---
EXPLICIT WORD
READ
ECHRD 4 106.8 106.8 158.9 176.3 220.3 --- ---
EXPLICIT WORD
WRITE
ECHWR 4 106.0 106.0 158.3 175.7 205.3 --- ---
Instruction Mne-
monic
Length
(steps)
ON execution time (µs) Conditions
CJ1H
CPU6@
H-R
CJ1H
CPU6@
H
CJ1G
CPU4@
H
CJ1M
CPU12/13/
22/23
CJ1M
CPU11/
21
CJ1G
CPU4@
READ
DATA FILE
FREAD 5 391.4 391.4 632.4 657.3 641.3 684.1 2-character directory
+ file name in binary
WRITE
DATA FILE
FWRIT 5 387.8 387.8 627.0 650.7 637.3 684.7 2-character directory
+ file name in binary
WRITE
TEXT FILE
TWRIT 5 390.1 390.1 619.1 555.3 489.0 --- ---
Instruction Mne-
monic
Length
(steps)
ON execution time (µs) Conditions
CJ1H
CPU6@
H-R
CJ1H
CPU6@
H
CJ1G
CPU4@
H
CJ1M
CPU12/
13/22/23
CJ1M
CPU11/
21
CJ1G
CPU4@
DISPLAY MES-
SAGE
MSG 3 10.1 10.1 14.2 16.8 17.3 14.3 Displaying message
8.4 8.4 11.3 14.7 14.7 11.3 Deleting displayed
message
Instruction Mne-
monic
Length
(steps)
ON execution time (µs) Conditions
CJ1H
CPU6@
H-R
CJ1H
CPU6@
H
CJ1G
CPU4@
H
CJ1M
CPU12/13/
22/23
CJ1M
CPU11/
21
CJ1G
CPU4@

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CJ - INSTRUCTIONS and is the answer not in the manual?

Omron CJ - INSTRUCTIONS Specifications

General IconGeneral
BrandOmron
ModelCJ - INSTRUCTIONS
CategoryController
LanguageEnglish

Related product manuals