3. Instructions
386
CS/CJ/NSJ Series Instructions Reference Manual (W474)
z In this example, N words of binary data is converted to BCD data.
If N = 3, the three words of binary starting from D10 will be converted to binary data one word at a time
when CIO 0.00 turns ON. The resulting BCD data will be stored starting from D100.
D100
BIN
BCD
D101
D102
D10
D11
D12
NEXT
BCD
,IR0+
FOR
&3
,IR1+
MOVR
D10
IR0
MOVR
D100
IR1
0.00
0.00
BCD #0200
BCD #0100
BCD #0300
Decimal &200
Decimal &100
Decimal &300
(Hexadecimal #00C8)
(Hexadecimal #0064)
(Hexadecimal #012C)