EasyManua.ls Logo

Omron CJ - INSTRUCTIONS

Omron CJ - INSTRUCTIONS
1308 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. Instructions
490
CS/CJ/NSJ Series Instructions Reference Manual (W474)
Precautions
z SINQ, COSQ
SINQ(475)/COSQ(476) differs from SIN(460)/COS(461) in the following respects:
The instruction has improved performance.
The instruction length is 8 steps.
The Condition Flags are not refreshed.
An unpredictable value will be output if the angle data is out-of-range.
The data cannot be input or output at a Programming Console. A question mark will be displayed.
z TANQ
TANQ(477) differs from TAN(462) in the following respects:
The instruction has improved performance.
The instruction length is 15 steps.
The Condition Flags are not refreshed.
An unpredictable value will be output if the angle data is out-of-range.
The data cannot be input or output at a Programming Console. A question mark will be displayed.
An unpredictable value will be output if the angle data is nπ/2
(n = ...., -3, -1, 1, 3.....).