How to use
62
PreparationSafety precautions Help Appendix
Changing the overload alarm detection time
You can change the time till the overload alarm is detected after the motor output torque exceeded the overload detection level.
The time when the overload alarm is generated varies according to the load factor of the motor.
Overload alarm detection time
The time set in the "Overload alarm detection time" parameter (ID: 384) is an operating time at the following load factor.
200 W or lower: About 180%
300 W or higher: About 150%
z
200 W or lower
100 150 200 250
300
Load factor [%]
180
0
10
60
50
40
30
20
Overload alarm detection time [s]
Overload alarm detection time (reference)
Area for transistor
protection
z
300 W or higher
100 150 200 250
300
Load factor [%]
0
10
60
50
40
30
20
Overload alarm detection time [s]
Overload alarm detection time (reference)
Setting value
: 1 second
: 5 seconds
: 10 seconds
: 15 seconds
: 20 seconds
: 25 seconds
: 30 seconds
: 35 seconds
: 40 seconds
Operating the motor by ON-OFF control of the power supply
The “Prevention of operation at power-on alarm” parameter is set to enable at the time of shipment in order to prevent the motor
from rotating suddenly when the power is turned on.
Setting the “Prevention of operation at power-on alarm” parameter to disable can operate or stop the motor by ON-OFF control
of the power supply of the driver.
Note
Execute an operation after conrming thoroughly that no risk occurs by rotation of the motor.
z
Setting procedures
1. Set the "Prevention of operation at power-on alarm" parameter from “1 (Enable)” to "0 (Disable).
2. Set a rotation speed in the operation data.
If the operation data number is not selected, the motor rotates at the rotation speed set in the operation data No.0. To use an
external analog setting device, change the “Speed, torque limiting command selection” parameter.
3. Turn the operation input signal (FWD input or REV input
*
) ON.
Input a signal indicating the motor rotation direction desired.
*
In the case of 2-Wire mode
4. Turn o the driver power. Turn on the power again, and the motor will rotate immediately.
To stop the motor, turn o the driver power or turn the operation input signal OFF.
3-4 Operation parameters
B: Update after operation stop, C: Update after executing conguration or turning on the power again
ID Parameter name Description Setting range
Factory
setting
Update
2069
Load holding function
selection
Sets whether a certain degree of holding force is generated when
the motor stops.
0: Disable
1: Enable
0 C
329
Acceleration/deceleration unit
selection
Sets the setting unit for the acceleration time and deceleration
time when setting the rotation speed to the digital setting.
0: [s / 3000 r/min]
1: [s]
0
B
330 Impact softening lter
This is a function to soften an impact at starting and stopping
against the set acceleration time and deceleration time.
0: No lter
1: Filter 1
2: Filter 2
0