EasyManua.ls Logo

Oriental motor BLE2D60-A - Connecting External Analog Setting Devices

Oriental motor BLE2D60-A
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Preparation
21
Safety precautions How to use Help Appendix
5. Connecting external analog setting devices
Using an external potentiometer (sold separately) or external DC voltage, the analog setting for the rotation speed or torque
limiting value can be performed.
Refer to p.38, 41 and p.59 for the setting method.
Using an external potentiometer
Connect to the pin Nos. 12 to 14 of CN5.
Pin No.13 VM input
Pin No.12 VH input
CN5
Pin No.14 VL input
External potentiometer
0 to 20
k
1
3
2
Using external DC voltage
For the external voltage, use a DC power supply (0 to 10 VDC) with reinforced insulation on its primary and secondary sides, and
connect to the pin Nos. 13 and 14 of CN5.
The input impedance between the VM input and VL input is approximately 41.8 k
Ω
.
The VL input is connected to IN-COM1 inside the driver.
0 to 10 VDC
1 mA or more
External DC
power supply
Pin No.13 VM input
Pin No.14 VL input
CN5
Note
Be sure to use the external DC voltage at 10 V or lower. When connecting the external DC power supply, make sure the
polarities are correct. Reversing the polarities may cause damage to the driver.