them to a centralized rsyslog server.
In order to get rsyslog daemon sending all logs to a server, /etc/rsyslog.conf should be con-
figured with the following lines:
module(load="imfile")
input (type="imfile"
File="/var/log/systemlog"
Tag="custom"
Facility="local0"
Severity="info")
local0.* @<rsyslog server1 IP>
local0.* @<rsyslog server2 IP>
9.2.6 Warranty
The WR-Z16 device is fully factory tested and warranted against manufacturing defects
for a period of one year. Failure of the WRZ device due to installation problems caused by
the circumstances under the WRZ device is installed cannot be warranted. This includes
misuse, miswiring, overheating, operation under loads beyond the design range of the WR-
Z16 device.
For warranty or non-warranty replacement please write to our "Technical Support" on the
facing page team at TimingSupport@orolia.com.
9.2.7 Contact
For more information about our company and products please contact us:
See "Technical Support" on the facing page, or:
Website https://sevensols.com/
Address Seven Solutions S.L.
Calle Periodista Rafael mez Montero,
2 CETIC-UGR 13, 18014
Granada SPAIN
Phone (+34) 958 285 024
Email info.spain@orolia.com