VSC HO
Device
Status
Message
Clock
Class
Active
Reference
Description
VSC-
20110
WARNING Locked: Time of
Day not available
on GM
6 BC:
WR/PTP
@ ifname
The GM announce a problem
that its ToD has not been
properly set since start. Prob-
ably due to an NTP error, the
GM will stay there until
restarting/re-evaluation of
GM
VSC-
20111
WARNING Locked: Leap
seconds file on
GM has expired
6 BC:
WR/PTP
@ ifname
The GM time is announced
has valid but the utc_offset is
not valid. This means that
leapsec file has expired at
GM
9.4.3 Others
VSC HO
Device
Status
Message
Clock
Class
Active
Reference
Description
VSC-
09000
OK Timing
source is
ready
X X For ports, "Ready" means that the
link is up and some announce mes-
sages sent by a master has been
received. For GM, "Ready" means
that 10M/PPS has been detected
properly
VSC-
09100
CRITICAL System
Error
248 Internal
Oscillator
In case we get an unexpect behavior
because some of the src modules
(ppsi,ptpd,gnss,hald) has crashed,
The tmgr will enforce this status in
order to alert to the managment and
also to other nodes (if possible) that
our current situation is unexpected.
VSC-
09110
WARNING Initializing... 248 Internal
Oscillator
The device will always initialize with
the following configuration before
using any policy/strategy/src in
tmgr. The following value are only
written in case the user run: /etc/in-
it.d/tmgrd restart
VSC-
90000
OK Manual
Free-run-
ning
193 Internal
Oscillator
The device has been manually set as
FR master and thus will distribute
time according to its own reference
146 WR-Z16 User Manual