PTP With License Without License
Sync ratio [1 msg/128s,128 msg/s] ([-7,7]) 1 msg/sec
Delay Req ratio [1 msg/128s,128 msg/s] ([-7,7]) 1 msg/sec
Clock Quality & Timing Properties
Clock Class From VCS or user defined (0-255) 248
Priority1 From VCS or user defined (0-255) 128
Priority2 From VCS or user defined (0-255) 128
Clock Accuracy From VCS (See
"External Reference (GM)" on
page73
)
Unknown
Variance From VCS 65535 (maximum)
Timing Source From VCS (See
"External Reference (GM)" on
page73
)
OTHERS
Traceability Flags From VCS False
PTP Timescale From VCS or user defined True
UTC Offset From VCS 37
Advanced Settings
Offset correction Any number (in nanoseconds) 0
Servo Fit
Algorithm
Normal, Soft, Hard, Hardx2 Normal
5.4.1.1 PTP license management
All the topics related to PTP license management such as purchasing, activating and check-
ing are explained within the Licenses section ("Licenses" on page120).
Once the license is activated (see image below) the web interface should allow the user to
configure these settings as explained in "Configuration" on the facing page.
Figure 5-15: Unlicensed VS Licensed PTP daemon